Vitatron C-series 2nd generation




Vitatron C-series 2nd generation
It’s digital – it’s fast



Vitatron C60 DR
Vitatron C50 D
Vitatron C20 SR
Vitatron C10 S

The Vitatron C-series 2nd generation are the second series of pacemakers that builds on Vitatron’s innovative digital technology. It is a family of digital pacemakers for patients suffering from bradycardia. New therapies are introduced to minimize patient symptoms and improve hemodynamics. Furthermore the improved interrogation and analysis of the pacemaker data, makes the pacemaker the fastest available and helps you make quick and well-informed decisions.

Fast
Vitatron C-series provides fast and easy follow-up.

  • Fastest pacemaker interrogation in the industry
  • All settings can be reprogrammed in only 1 second
  • Streamlined follow-up with Therapy Advisor
  • Historical data of up to four previous follow-ups

Complete interrogation in less than 17 seconds; all settings can be reprogrammed in only 1 second.

  • Device identification
  • Battery status and lead impedance
  • All diagnostics and parameters
  • Therapy Advisor validation and analysis of all data


Digital
Vitatron C-series is the worlds first pacemaker with Digital Signal Processing (DSP). DSP switches the analogue signal into a digital signal. The digital platform offers a wide array of new possibilities to improve therapies and device functionalities. The signal processing of the digital platform is much faster, there is more storage capacity and all diagnostics are available during initial interrogation. The digital pacemaker generates more precise morphology parameters which results in a high-quality, on-screen IEGM


  • High 800 Hz sampling frequency for P-and R-wave measurements


  • Accurate diagnostics for more appropriate therapy


  • High quality intracardiac electrogram (IEGM)

 

Confident
The combination of new digital technology with Vitatron’s unique proven therapies allows you to confidently deliver optimal therapy, expanded diagnostics and fast, easy follow-up. The Vitatron C-series continues to deliver proven therapies for bradycardia. The pacemaker determines whether to pace or not on a beat-to-beat basis All diagnostics are available during initial interrogation of the pacemaker. Therapy Advisor™ automatically and rapidly analyzes diagnostic data, giving you programming suggestions to optimize pacemaker settings. New therapies like Refined Ventricular Pacing (RVP) and Ventricular Rate Stabilization (VRS) are introduced to minimize patient symptoms and to improve hemodynamics. Furthermore, Vitatron’s beat-to-beat Mode Switching preserves a balanced ventricular rate.

  • Promote physiological pacing
  • Appropriate ventricular pacing
  • Minimize patient symptoms

Refined Ventricular Pacing (RVP) reduces unnecessary ventricular pacing
Reduction of ventricular pacing may lead to:

  • Improved hemodynamics1
  • Decreased hospitalization for congestive heart failure2
  • Decreased incidence of atrial arrhythmia2

Refined Ventricular Pacing expands options to promote intrinsic AV conduction

  • Programmable AV delay extension
  • Scanning rate automatically changes with AV delay extension



Ventricular Rate Stabilization (VRS) significantly reduces R-R irregularity to minimize symptoms

  • An irregular ventricular response to Atrial Fibrillation (AF) may lead to patient symptoms3
  • VRS significantly reduces R-R variability during episodes of conducted AF4
  • 70% of symptomatic Paroxysmal Atrial Fibrillation (PAF) patients with intact conduction preferred VRS turned 'On'.
  • Continuous diagnostics help identify patients who will respond well to this therapy4.

VRS aims to reduce ventricular irregularity during atrial tachyarrhythmia to reduce patient symptoms.By increasing the rate to just above the average underlying ventricular rate, long VV intervals are eliminated and the occurrence of very short VV intervals is significantly reduced.





In the Vitatron C-series 2nd generation, the Therapy Advisor has been extended to include therapy-based suggestions on Ventricular Rate Stabilization (VRS) and Refined Ventricular Pacing (RVP).

1 Nielsen J, et al. JACC. 2003; 4:614-23.
2 Sweeney M, et al. PACE. 2002;24(Pt II):561 [abstract]
3 Yee R, et al. 10th International Symposium on Progress in Clinical Pacing, Rome 2002 [abstract]
4 Yee R, et al. American Heart Association Scientific Sessions 2003 [poster]

The programmer used in combination with the Vitatron C-series offers a clear and organized programmer screen and is easy to use.

Education
The Vitatron Education Center can offer you standard or tailor-made education programs/sessions on the new Vitatron C-series. Please contact your local Vitatron representative in case of any educational requests.