Selection 9000 AF3.0

Selection 9000 AF3.0
Expanding your AF treatment options


Selection 9000 AF3.0
PreventAF (model 920)
DiagnoseAF (model 910)


New AF therapies for rhythm and rate control

Vitatron continues its tradition of unique solutions for AF with the introduction of the Selection 9000 AF3.0. This cardiac stimulator offers a series of AF monitoring diagnostics, new AF prevention pacing therapy and new rate control therapies. AF-patients who already have a Selection 9000 can benefit from these new treatment options without having to undergo another invasive implant procedure. They will be the first patients to undergo a groundbreaking therapeutic upgrade.

Upgrade
AF treatment strategies change rapidly and continuously. The AF3.0 therapeutic upgrade gives physicians the unique opportunity to quickly adapt new AF pacing solutions and give patients the newest therapies without additional invasive surgical procedures. Vitatron is the first to introduce industry exclusive therapeutic upgrades. AF patients who have the Selection 9000 can benefit from new rhythm and rate control therapies for AF without having to undergo a new implant. During their next follow-up visit they will be given an AF3.0 upgrade automatically. This means less surgical procedures and fewer hospitalizations, a breakthrough for patients and less burden on healthcare.

AF monitoring diagnostics
With the Selection 9000 AF3.0 Vitatron offers AF monitoring diagnostics which allow for early detection and diagnosis of AF, monitor disease progression, evaluate AF treatment success and assess AF burden. Vitatron’s unique Beat-to-Beat atrial rhythm monitoring ensures instant recognition of irregularities.

 

Atrial rhythm control
The Selection 9000 AF3.0 offers an extensive array of AF prevention pacing therapies. The therapies in the Selection 9000 AF3.0 consist of four algorithms for triggered overdrive pacing which reacts to onset triggers of AF: PAC Suppression, PAC Response, Post-AF Response and Post-Exercise Response. In addition, there are two more algorithms for continuous overdrive pacing which aim to condition the atrial activation pattern by dynamically overdriving the atrial rate: Pace Conditioning and Rate Soothing. This combination of continuous AF monitoring and six preventive pacing therapies enables physicians to fine-tune treatment. With the Selection 9000 AF3.0 they can provide a “tailor made” therapy with the right pacing rhythm for every patient.

Clinically, AF prevention pacing therapies can:

  • promote and maintain normal sinus rhythm
  • improve hemodynamics
  • reduce risk of stroke
  • Improve quality of life

 

Ventricular rate control
In some patients atrial fibrillation also affects the ventricles. The Selection 9000 AF3.0 is a cardiac stimulator that offers ventricular rate control algorithms as a solution to this problem. Ventricular Rate Stabilization, promotes a stable ventricular rate during AF episodes and is aimed to reduce patient symptoms. For pacemaker dependent patients, the Selection 9000 AF3.0 offers Beat-to-Beat Mode Switching to prevent tracking of high atrial rates.

Clinically, rate control can:

  • limit patient’s symptoms
  • improve hemodynamics
  • improve quality of life

 

top | disclosure